RIKA Memo Service Manual Page 25

  • Download
  • Add to my manuals
  • Print
  • Page
    / 36
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 24
|25
EN
24
9. MODES
Note
When operated correctly, your stove can not overheat. Improper operation
may shorten the life expectancy of electrical components (blowers, motors
and electric control) and is not allowed!
Pellet operation Heat/Easy/Automatic/Room
HEAT/EASY
The pellet burner start and stop as well as the setting of the required heat
output are executed directly in the HOME – main menu.
AUTOMATIC MODE
The change between standby operation and neutral as well as the setting of the
required heat output are executed via the display in the HOME – main menu.
The pellet burner starts in standby mode within the heating times when the
actual room temperature is below the set room temperature, or outside of
the heating times when the actual room temperature is below the set room
temperature.
When achieving the set room temperature, the pellet burner stops.
Stove start is not possible in neutral status (OFF), the system is switched off.
ROOM MODE
The change between standby operation and neutral as well as the setting of the
required heat output are executed via the display in the HOME – main menu.
The pellet burner starts in standby mode if the actual room temperature is
below the set room temperature.
When achieving the set room temperature, the pellet burner stops.
Stove start is not possible in neutral status (OFF), the system is switched off.
Fuel addition pellet operation
Note
CAUTION when filling! Do not allow the pellet sack to come into contact with
the hot stove. Immediately remove any pellets that have not entered the
supply container!
We recommend maintaining an appropriate level in the supply container to
prevent the fire going out due to lack of fuel. A 15 kg sack of pellets can be
added to the stove once half the pellets in the container have been used up.
Check the level frequently. However the container lid should be kept closed,
except during filling.
When filling the container during operation (opening of the container lid), the
fan is started up and the pellet conveyor is stopped; operation is only resumed
once the container lid is closed (see WARNING AND ERROR MESSAGES)
Pellet container capacity (see TECHNICAL DATA).
Emergency - electrical heating up. without
ignition
Should the units ignition cartridge fail, an emergency operation can be
performed with using fire (ignition cubes). First, start the oven as usual. Wait for
the flushing and the tilting of the grate. Then you open the firebox door and give
a handful of pellets with the ignition cubes in the clean burning trough, ignite it
and then close the firebox door.
Note
Do not use flammable liquids to ignit the stove!