FLUE GAS FAN HOUSING
This maintenance procedure should be car-
ried out dependent on the fire usage and the
fuel used, as frequently as required.
In order to inspect the flue gas fan and to
clean it, remove four screws (see drawing)
and pull the motor out of the housing care-
fully. Remove the flue dust from the fan and
flue gas outlets using a vacuum cleaner.
When closing care must be taken that there
are no leaks.
Only carry out maintenance when the mains
plug of the fire has been removed from the
socket.
Note: All motors have sealed ball bearings.
Lubrication is not required!
FUEL CONTAINER
Do not fill the container up again immedia-
tely but remove residues (dust, chips etc.)
from the empty container using a vacuum
cleaner and the RIKA Ashbox.
DOOR SEAL
The state of the seals on the doors and
glass should be checked from time to time.
Repair or replace the seals dependent on
the state.
e
very six months!
FLUE CONNECTION
Inspect and clean the connection. The col-
lected flue dust can have a negative effect
on the fire performance and represent a
safety risk.
AIR SENSOR
The sensor should be maintained and cle-
aned by an authorised service technician.
±
Cleaning should be carried out using a
soft brush.
±
Ensure the fitting is correct (the print
plate must be at the front).
MAINTENANCE AND CLEANING Con’t
25
Combustion Motor Housing
the combustion fan
Only carry out maintenance when the power
cord has been removed from the wall.
HOPPER
hopper
as needed.
ash from fan and out-
lets using an approved vacuum cleaner.
Replace the combustion motor
gasket as required.
done on a regular basis depending on fuel
quality and amount of useage.
At least once a year, allow your hopper to empty
completely and vacuum out the bottom of the hopper
assembly.
Door Gasket
The condition of the gasket on the doors and
Repair or replace in order to maintain air
tight seal.
Inspect and clean the chimney system.
The collected ash can have a negative
effect on the stove performance and
represent a safety risk.
The air sensor should be maintained and
cleaned by an authorized service technician.
Cleaning should be carried out using a non-
petroleum based electronic spray.
EVERY SIX MONTHS